Posts Tagged ‘North Miami Beach’

Air Conditioning Question From West Palm Beach: What Are Thermostatic Expansion Valves?

Monday, April 30th, 2012

The thermostatic expansion valve, sometimes known as a TEX, TEV or TXV, is a critical piece to influence the efficiency of air conditioning and refrigeration units.  A tiny sensor controlling the evaporating phase of process, the valve can have a big effect.

Cool air is manufactured by a rapid movement of a refrigerant between liquid and gaseous states.  Compound chemicals that are able to do this at a low temperature are compressed and expanded, absorbing and releasing heat at different points along the way.  The TEV controls the flow of the refrigerant into the evaporator coils according to the temperatures of the various ingredients.

Cool Air 101

To condition air, the refrigerant, most often freon or another fast acting, low temp compound, evaporates into a gas that runs through a coil and absorbs heat.  Passing through a compressor, the freon condenses under pressure back into a liquid again and releases the heat, becoming cool enough to chill a party.

Too much freon in the evaporator tube and the pressure is not low enough to expand to gas and absorb heat, working inefficiently for no gain.  Too little freon and the conversion is also ineffective by not reaching the density needed to condense.

There are four types of valves with different benefits for different types of cooling environments.  With its ability to adjust minutely to changing conditions, the thermal expansion valve creates the perfect mixture of pressure and freon for more complicated systems.

At the Starting Gate

An interactive device, the valve senses the evaporator pressure and temperature and adjusts the flow of the refrigerant so as to maintain a given “superheat”, the differ­ence between the refrigerant vapor temperature and its sat­uration temperature.  By controlling superheat, the TEV keeps nearly the entire evaporator surface active while not permit­ting liquid refrigerant to return to the compressor.

Some valves operate on an electrical impulse from sensors that can measure the temperatures.  Others are open all the time.  The thermostatic expansion valve actually utilizes the pressure between the two sections to open or close itself, regulating flow based on the very same pressure it is designed to moderate.

Like the buildings they comfort, central air conditioning systems in West Palm Beach are varied and diverse.  There are nearly as many thermostatic expansion valves as there are units to receive them. For more information about how you air conditioner works and ways to maintain it, talk to Envirotech Air Quality Services!

Things to Check on Your Broken AC Before Calling a West Palm Beach Air Conditioning Professional

Monday, April 23rd, 2012

A broken air conditioner is a stressful situation, especially since you’re considering whether you need a West Palm Beach air conditioning professional to come out. No one likes spending money to have a professional take a look at their system, so before you call anyone, make sure to check these problems. You may be able to fix the problem on your own without spending a dime.

 Thermostat

The thermostat is one of the most common problems you’ll have with an air conditioner.  Make sure the thermostat wasn’t knocked out of position and the sensors near your coils are in the right place. Often times, a bumped sensor or a slightly off thermostat can cause this kind of problem and as a result, you’ll be left without steady cooling.

 Check Your Filters

Another common problem that can cause issues with your air conditioner is filter clogging. While the system will continue to run with a clogged filter, there are a few issues that might pop up – it could smell funny or you might notice icing on the outside line (a major problem). If you allow the filter to get so clogged as to block the air flow from your system, you can expect a number of problems to crop up.

 Blower Belts

Check the system’s blower belt for damage like cracking, excess slack or general wear. A blower belt that isn’t properly installed or that needs to be replaced will reduce air flow which can result in ice buildup or poor air flow – it will make it harder for your system to maintain a steady temperature.

 Check the Outdoor Unit

Check to make sure nothing is blocking the outdoor unit. Clean the condenser coils and remove any debris that might have built up around the outdoor unit. Often, slowed air flow is caused by nothing more than leaves piled in front of your condenser.

If none of these problems is the culprit or if you fix them all and your system continues to struggle, it is time to call a West Palm Beach air conditioning professional like Envirotech Air Quality Services!